The following information details the steps required to configure X-RTCM corrections between two LD5 units.
- Prepare two 9 way D-Type (male both ends) cross over cables with pins 2 and 3 crossing at either end:
9 Pin Male 9 Pin Male
2 ------------------------------ 3
3 ------------------------------ 2
2 ------------------------------ 3
3 ------------------------------ 2
5 ------------------------------ 5
- Connect the cables to serial port one on the rear of both LD5 units. Then connect the other cable end to serial port three on the rear of both LD5 units (if ports 1 or 3 are not free port 2 could be used).
- Check the software version of the LD5 unit by selecting Config then Config:
For versions 5.0.0.17 and later (for earlier versions see below)
- On the first LD5 unit enter the Config menu from the home screen and then select I/O from the next menu:
- Select COM1 from the next menu, then on the Data Stream tab select LBand RTCMa then Next:
- On the next page select Protocol: RS232, Baud 9600, Data Bits: 8, Parity: None and Stop Bits: 1. Then select Apply:
- Return to the Config I/O page, and select COM3, then on the Data Stream tab select Ext RTCM, then Next:
- On the next page select Protocol: RS232, Baud 9600, Data Bits: 8, Parity: None and Stop Bits: 1. Then select Apply:
- Once the unit has updated it will return to the Config I/O page, but now there will be an EXT RTCM tab available.
- Select the EXT RTCM tab and on the next page select RTCM Source: Veripos, then Apply:
- Once the unit has updated it will return to the Config I/O page. Press the Home button as the configuration on this unit is complete.
- On the second LD5 unit repeat steps 1-8.
- Once these steps are complete press the Home button. The configuration is now complete, and X-RTCM should be available on both LD5 units. This can be tested by disabling the L Band corrections on the first LD5 unit, and ensuring that the Latency on the Orion display for this unit does not change. The L Band lock indicator on the Orion display should be red at this time. Once satisfied, re-enable the L Band corrections for this unit, and repeat the procedure on the second LD5 unit.
For versions 4.0.0.9 and earlier
- On the first LD5 unit enter the Config menu from the home screen and then select Routing from the next menu:
- Select COM1 from the next menu, then on the Data Stream tab select LBand RTCMa, then Next:
- On the next page select Protocol: RS232, Baud 9600, Data Bits: 8, Parity: None and Stop Bits: 1. Then select Apply:
- Return to the Config I/O page, and select COM3, then on the Data Stream tab select Ext RTCM, then Next:
- On the next page select Protocol: RS232, Baud 9600, Data Bits: 8, Parity: None and Stop Bits: 1. Then select Apply:
- Once the unit has updated it will return to the Config I/O page, but now there will be a 3rd-Party RTCM tab available.
- Select the 3rd-Party RTCM tab and on the next page select EXT RTCM: On, then Apply:
- Once the unit has updated it will return to the Config I/O page. Press the Home button as the configuration on this unit is complete.
- On the second LD5 unit repeat steps 1-8.
- Once these steps are complete press the Home button. The configuration is now complete, and X-RTCM should be available on both LD5 units. This can be tested by disabling the L Band corrections on the first LD5 unit, and ensuring that the Latency on the Orion display for this unit does not change. The L Band lock indicator on the Orion display should be red at this time. Once satisfied, re-enable the L Band corrections for this unit, and repeat the procedure on the second LD5 unit.